Insulated Panels
Acoustic Panels - Rockwool Sound Insulation
Rockwool-cored sandwich panels engineered for sound reduction up to 58dB Rw. A1 non-combustible. Ideal for machinery rooms, studios, plant enclosures and acoustic partitions.
Up to 58dB RwA1 Non-CombustibleAlpha w 0.95CE EN 13162
58dB
Max Rw
A1
Fire Class
0.95
Alpha w (NRC)
40-150
Thickness (mm)
Sound Reduction by Thickness
| Thickness | Rw (dB) | Typical Use |
|---|---|---|
| 40mm | 38 | Office partitions |
| 60mm | 44 | Meeting rooms |
| 80mm | 49 | Workshops |
| 100mm | 53 | Plant rooms |
| 120mm | 56 | Generator enclosures |
| 150mm | 58 | Acoustic studios |
Surface Finish Options
| Microperforated Steel | Improves NRC by 15-20% |
| Core Density | 80-140 kg/m³ Rockwool |
| Panel Width | 1,000 or 1,140mm |
| Joint System | Tongue and groove, acoustic sealant |
| Fire Class | A1 Non-Combustible |
| Certification | CE EN 13162, ISO 9001:2015 |
| Coatings | Polyester, PVDF, perforated white |
Features & Applications
| ✓ Plant Room Enclosures Reduce machinery noise transmission to occupied areas | ✓ Generator & Compressor Rooms A1 fire-rated enclosures meeting insurance requirements |
| ✓ Recording & Broadcast Studios High NRC microperforated finish for room acoustics | ✓ Office & Meeting Room Partitions Demountable acoustic walls for open-plan offices |
| ✓ Industrial Workshops Compliance with workplace noise exposure regulations | ✓ Data Centres HVAC and generator noise isolation for facilities |
Frequently Asked Questions
What is the difference between sound insulation (Rw) and sound absorption (alpha w)?
Rw measures how much sound a panel blocks between two spaces (sound transmission loss) – higher is better, up to 58dB for ARCOPAN panels. Alpha w measures how much sound a panel absorbs inside a room to reduce echo and reverberation – a value of 0.95 means 95% absorption. Microperforated finishes improve alpha w without significantly affecting Rw.
Which thickness do I need for my application?
For office partitions, 40-60mm (Rw 38-44dB) is typically sufficient. Plant rooms and compressor enclosures usually require 100-120mm (Rw 53-56dB). Recording studios and high-noise generator rooms benefit from 150mm (Rw 58dB). Our engineers can recommend exact thickness based on source noise level (dB) and target receiving-room level.
Are acoustic panels fire-rated?
Yes. All ARCOPAN acoustic panels use a Rockwool core achieving A1 non-combustible classification under EN 13501-1 – the highest fire rating available for sandwich panels, making them suitable for plant rooms, generator enclosures and other fire-sensitive areas.
What surface finish should I choose?
Standard polyester or PVDF coated steel provides good Rw performance and is easy to clean. Microperforated steel facings improve in-room sound absorption (higher alpha w), reducing echo – recommended for studios, gyms and large workshop spaces where reverberation is a concern.
What certifications and test reports are available?
Panels are CE marked under EN 13162. Acoustic performance is tested to EN ISO 10140 (sound insulation) and EN ISO 354 (sound absorption). Full test certificates, CE Declaration of Performance and ISO 9001:2015 documentation are provided on request for tender submissions.
Request a Technical Quote
Engineers respond within 24 hours. Acoustic test reports and CE DoP on request. EXW to DDP worldwide.